TECHNICAL TOOLS

Heating values of different fuels.

When comparing fuels, consider their lower heating values together with the measurement conditions.
Find IEA-sourced tables and explanatory notes together on this page.

SOLID FUELS

Coal, coke and wood.

IEAANNEX 2 / ANNEX 3

The lower heating value is labelled “Net Calorific Value” in the source tables. Approximate heating values for wood at different moisture levels are shown in a separate table. Unit equivalence: 1 GJ/t = 1 MJ/kg. These are typical values, not confidence intervals or boiler acceptance limits.

Hard coals and cokes · IEA, Tables A3.5–A3.6
FuelLower heating value (MJ/kg)Approx. kcal/kgTable
Anthracite28.95–30.356,915–7,249A3.5
Coking coal26.6–29.86,353–7,118A3.5
Other bituminous coal22.6–25.55,398–6,091A3.5
Metallurgical coke27.456,556A3.6
Gas coke27.916,666A3.6
Low-temperature coke25.46,067A3.6
Petroleum coke (green)30–35.37,165–8,431A3.6
Wood · IEA, Annex 2, p. 180
Fuel / moisture conditionApproximate heating value (MJ/kg)Approx. kcal/kg
Freshly cut (green) wood8.21,959
Dry wood (10–20% moisture)163,822
Oven-dried wood184,299

The wood values are the approximate heating values given on p. 180 of the source; that section does not separately distinguish net and gross values. As moisture increases, the available heat decreases. When stating a moisture percentage, the wet or dry basis must also be specified.

The referenced pages provide no separate numerical values for lignite, pellets, wood chips, olive pomace or agricultural biomass. Page 181 discusses sawdust, wood pieces and agricultural residues; moisture content and heating value must be established using manufacturer data or fuel analysis. Inclusion in the table does not mean that a fuel is suitable for every boiler.

Conversion: 1 kcal (IT) = 4.1868 kJ; kcal/kg = MJ/kg × 1,000 / 4.1868. Results are rounded to the nearest whole number (p. 185).

LIQUID AND GASEOUS FUELS

Petroleum products and methane.

IEAANNEX 3

Lower heating values are given on a mass basis, in MJ/kg. They should not be compared directly with volume-based values for gases.

Selected liquid and gaseous fuels · IEA
FuelLower heating value (MJ/kg)Source
Propane46.33A3.8
Butane45.72A3.8
LPG¹46.15A3.8
Gas oil / diesel oil43.38A3.8
Fuel oil, low sulphur42.18A3.8
Fuel oil, high sulphur41.57A3.8
Methane²50.03p. 187

¹ The LPG value applies to a mixture of 70% propane and 30% butane by mass. In Table A3.8, the net calorific values of naphtha and heavier fuels are taken as 95% of the gross value.

² The methane value applies to pure methane; it cannot be used directly for natural gas or biogas. The referenced pages do not provide a lower heating value for biogas. The actual value for LNG/CNG and natural gas depends on gas composition. Table A3.9 gives gross calorific values and is therefore not included in the lower heating value table.

SOURCE AND UNITS

Source: International Energy Agency (IEA), Energy Statistics Manual / Enerji İstatistikleri El Kitabı, Turkish edition, Annex 2, pp. 179–181 and Annex 3, pp. 183–187. The net calorific value columns are used for coal, coke and petroleum products; for methane and wood, the explanatory notes in the relevant sections are used. Download the IEA source PDFTR. Publisher’s publication page.