Solid/Liquid/Gas-Fuelled Hot Water and High-Temperature Hot Water Boiler

Obsidyen.

Water heating with different fuel options.

For solid fuel: a moving grate with water and air cooling, clinker crushing and ash discharge. Switching between fuels is possible; different fuels are not burned simultaneously.

Thermal output rangeSolid fuel: 750,000–5,000,000 kcal/hLiquid/gas fuel: 1,500–10,000 kW
Operating pressure1–14 barG
FuelSolid / liquid / gas fuel
Manufacturing approachMade to order
DESIGN APPROACH

We design your boiler room as a complete system.

We approach Obsidyen as an integrated boiler room solution based on your facility’s heat demand and the fuel it will use. We plan the boiler with equipment that works as a coordinated system, from fuel storage and handling to the water circuit, combustion air and flue gas discharge.

For solid-fuel operation, the ground-level hopper, conveyor belt or screw, and boiler hopper form the feeding line. Hydraulic feed rams, the moving grate and clinker crusher are assessed together with the combustion arrangement in the water-jacketed pre-furnace.

We engineer the water supply, return and expansion lines together with the fresh air fan, multicyclone, flue gas fan and chimney. For liquid or gaseous fuel, we assess burner compatibility and fuel pipework separately.

Access to maintenance doors, ash removal areas, ventilation and the location of automation controls for operator monitoring are also part of the layout design. This allows us to plan the boiler room around daily operation and maintenance needs. Final equipment selection and scope of supply are determined for each project and order.

Front isometric view
Click a number in the drawing to see the equipment name.
Obsidyen boiler room front isometric layout; equipment numbered 1–29 1. Liquid/gas-fuelled hot water boiler 1 2. Front smoke box 2 3. Burner mounting cover 3 4. Rear smoke box (ADS) — at the rear, schematic position 4 5. Water supply line (hot water) 5 6. Expansion line 6 7. Water return line (cold water) 7 8. Shunt line 8 9. Rear smoke box (ADS) cleaning ducts — at the rear, schematic position 9 10. Multicyclone connection ducts 10 11. Multicyclone 11 12. Flue gas fan — at the rear, schematic position 12 13. Chimney 13 14. Water-jacketed solid-fuel pre-furnace with forward feeding 14 15. Boiler fuel hopper 15 16. Pre-furnace operating and maintenance door — at the rear, schematic position 16 17. Hydraulically driven grate system 17 18. Clinker crusher system 18 19. Boiler fuel hopper agitator 19 20. Hydraulically driven fuel feed rams 20 21. Fresh air fan (blower) 21 22. Multicyclone ash removal door 22 23. Multicyclone maintenance door 23 24. Concrete foundation 24 25. Ash removal door — at the rear, schematic position 25 26. Service door 26 27. Ground-level fuel hopper 27 28. Ground-level fuel hopper agitator 28 29. Fuel conveyor belt or screw 29
Dashed lines show schematic positions of equipment transferred from the rear isometric view and not visible from this angle. Layout and equipment may vary according to the order scope.
Front isometric view
Obsidyen boiler room front isometric layout; equipment numbered 1–29 1. Liquid/gas-fuelled hot water boiler 1 2. Front smoke box 2 3. Burner mounting cover 3 4. Rear smoke box (ADS) — at the rear, schematic position 4 5. Water supply line (hot water) 5 6. Expansion line 6 7. Water return line (cold water) 7 8. Shunt line 8 9. Rear smoke box (ADS) cleaning ducts — at the rear, schematic position 9 10. Multicyclone connection ducts 10 11. Multicyclone 11 12. Flue gas fan — at the rear, schematic position 12 13. Chimney 13 14. Water-jacketed solid-fuel pre-furnace with forward feeding 14 15. Boiler fuel hopper 15 16. Pre-furnace operating and maintenance door — at the rear, schematic position 16 17. Hydraulically driven grate system 17 18. Clinker crusher system 18 19. Boiler fuel hopper agitator 19 20. Hydraulically driven fuel feed rams 20 21. Fresh air fan (blower) 21 22. Multicyclone ash removal door 22 23. Multicyclone maintenance door 23 24. Concrete foundation 24 25. Ash removal door — at the rear, schematic position 25 26. Service door 26 27. Ground-level fuel hopper 27 28. Ground-level fuel hopper agitator 28 29. Fuel conveyor belt or screw 29
FUEL FEEDING & COMBUSTION

An operating arrangement
suited to your fuel.

Solid-fuel feeding

  1. Transfer from the ground-level hopper: Coal is conveyed from the ground-level hopper to above the boiler hopper by an inclined trough screw conveyor.
  2. Top loading into the boiler hopper: Coal leaving the screw conveyor drops into the hopper and falls by gravity towards the sliding feed opening.
  3. Forward feeding by the hydraulic ram: The ram pushes coal onto the inlet of the grate; its return stroke makes room for fresh fuel.
  4. Fresh air distribution through four outlets: The fan distributes fresh air into the space beneath the grate through four separate outlets. Air passes through the grate gaps to reach the fuel bed.
  5. Drying and preheating: In the first section of the grate, the fuel heats up, releases moisture and is prepared for ignition.
  6. Ignition: In the second section, the preheated fuel ignites and a flame starts to form.
  7. Combustion: Combustion intensifies in the third section. The forward motion of the moving grate advances the fuel gradually, while the air supply supports combustion.
  8. Burnout and cooling: In the fourth section, combustion is completed and the flames die out. Remaining ash and clinker begin to cool as they move towards the end of the grate.
  9. Crushing and ash collection: Residues at the end of the grate fall into the crusher. Counter-rotating rollers reduce larger pieces; ash and crushed clinker are collected in the ash trolley below.
TECHNICAL SPECIFICATIONS

Capacity, pressure
and boiler construction.

Obsidyen is designed for hot water and high-temperature hot water applications with a semi-cylindrical, four-pass, fire-tube construction. Fuel preparation, combustion and heat transfer are engineered together according to the selected capacity and the facility’s operating conditions.

Obsidyen technical specifications

Capacity and construction

Thermal output rangeSolid fuel: 750,000–5,000,000 kcal/h
Liquid/gas fuel: 1,500–10,000 kW
Operating pressure1–14 barG
Operating water temperatureEngineered to suit hot water or high-temperature hot water requirements
ConstructionSemi-cylindrical · Four-pass · Fire-tube
FuelSolid / liquid / gas fuel
Fuel feeding / combustionTop-fed hydraulic ram feeding or burner
Solid-fuel lower heating value2,000–7,500 kcal/kg
Minimum fuel particle sizeGreater than 8 mm
Maximum fuel sizeUp to 120 mm with hydraulic feeding
ManufacturingEngineered to order
Product familyHot Water & High-Temperature Hot Water Boilers

Material standards

Boiler steels In high-pressure sections:EN 10028-2 grade P355GH, P295GH, P265GH and P235GH
Steel grades In non-pressurized or low-pressure sections:EN 10025-2 grade S355JR, S235JR
Fire and smoke tubesEN 10217-2 or EN 10216-2 grade P235GH

The series is engineered to order within thermal output ranges of 750,000–5,000,000 kcal/h for solid fuel and 1,500–10,000 kW for liquid/gas fuel, and an operating pressure range of 1–14 barG. These are the series limits of units that can be manufactured at different capacities; they do not represent the load adjustment range of a single unit. Final capacity, operating conditions and equipment scope are determined for each project.

Fuel storage and transfer to the boiler hopper

Solid fuel is delivered to the boiler hopper from a storage area suited to the facility layout. If the system includes a ground-level hopper, a transfer screw or conveyor belt moves fuel between these two points. Fuel loaded into the hopper from above moves towards the feed opening.

Fuel moisture, ash content, size and flow characteristics are considered when selecting the transfer line. The ground-level hopper, agitator, level sensor and conveying equipment are determined by the order scope.

Hydraulic forward feeding and combustion on the moving grate

The hydraulic ram pushes fuel from the hopper outlet onto the inlet of the grate. Fixed and moving grate elements work together to advance the fuel bed gradually. Combustion air is distributed beneath the grate and passes into the fuel bed.

In the first zone, fuel heats up and loses moisture; ignition and intensive combustion occur in the following zones. Combustion is completed towards the end of the grate, and residues begin to cool. The water- and air-cooled moving grate forms part of this fuel movement and combustion arrangement.

Clinker crushing and ash collection

Ash and clinker produced after combustion are transferred from the end of the grate to the crusher. The crusher reduces large residues; crushed clinker and ash pass through the discharge line to the collection section. In the animated arrangement, this section is an ash trolley.

Ash quantity and clinker formation depend on the fuel properties. Access areas required for collection, emptying and maintenance are planned together with the boiler room layout.

Burner-fired operation with liquid or gaseous fuel

In the burner-fired option, liquid or gaseous fuel is delivered to the burner through a preparation and supply line suited to that fuel. The burner fan supplies combustion air; ignition, flame supervision and fuel–air adjustment are handled by the selected burner’s control system.

Switching between solid-fuel and burner-fired operation is possible; different fuels are not burned simultaneously. Switching must not be assumed to be automatic or uninterrupted. Burner compatibility, connections and switching conditions are defined within the project.

Four-pass fire and smoke gas path

Hot gases produced in the combustion chamber travel through the four-pass fire-tube arrangement. Reversal sections direct the gases into the next pass, allowing them to contact the heat transfer surfaces before reaching the outlet.

Energy from the hot gases is transferred to the boiler water surrounding the fire and smoke tubes and combustion surfaces. Cleaning the flue gas passages, checking deposits on heat transfer surfaces and providing maintenance access form part of the operating plan.

Flue gas discharge and auxiliary equipment

A multicyclone is available as an option for the flue gas line in solid-fuel operation. It separates some of the solid particles carried by the gas and collects them in a hopper. Equipment scope is determined for each project. Flue and duct dimensions, gas flow rate and the system’s pressure losses are assessed together.

Where a flue gas fan is required, it is selected according to the total resistance of the boiler and auxiliary equipment. The layout of the fan, dampers and cleaning doors is determined for each project; auxiliary equipment must not automatically be assumed to be included in the standard delivery.

Water heating and delivery to the installation

Water returning from the installation absorbs energy from the boiler’s heat transfer surfaces and is sent through the supply line to the service circuit. Circulation arrangements, target supply and return temperatures, and the system’s heat demand are assessed together.

The hot water or high-temperature hot water application is engineered for the selected temperature and pressure conditions. Expansion, pressure control and temperature limiting equipment is selected together with the installation. Water quality and adequate circulation are addressed in the operating plan to control corrosion and deposits.

Insulation, external cladding and maintenance access

To limit heat loss, hot surfaces are protected with insulation and external cladding suited to the design conditions. Insulation material, thickness and cladding details are determined by the operating temperature and order scope.

The combustion system, heat transfer surfaces and flue connections must be accessible for maintenance. Service clearances around the equipment, door opening directions and cleaning areas are considered when planning the facility layout.

FUEL COMPATIBILITY

The right configuration
starts with your fuel.

Solid fuels

Coal and lignite; wood, pellets and appropriately sized wood chips; olive pomace and agricultural biomass may be considered when the fuel conditions are met. Fuels containing plastic or unsuitable chemical additives are not accepted. A fuel name alone does not establish suitability; lower heating value, size, composition, moisture content and analysis requirements are assessed together.

Coal / LigniteWood / Pellets / Wood chipsOlive pomace / Agricultural biomass

Liquid and gaseous fuels

A suitable burner and fuel preparation system are selected for natural gas, LNG, CNG, LPG, diesel and fuel oil. For methane and biogas, gas composition, treatment requirements and burner compatibility are assessed separately. A single burner must not be assumed to support every fuel.

Natural gas / LNG / CNGLPGDiesel / Fuel oilMethaneBiogas

Switching between solid fuel and liquid/gas fuel is possible; different fuels are not burned simultaneously. Switching must not be assumed to be automatic or uninterrupted.

Open the unit converter
SOLID FUELS · IEA · LOWER HEATING VALUE≈ 1,959–8,431 kcal/kg

Solid-fuel and feeding requirements

The product’s current range for project assessment is 2,000–7,500 kcal/kg; this is separate from the typical values in the IEA table. Fuel size must be greater than 8 mm. With hydraulic feeding, the maximum is 120 mm.

LIQUID / GASEOUS FUELS · IEA · LOWER HEATING VALUE41.57–50.03 MJ/kg

When lower heating value changes, capacity may change too

All other conditions being equal, more of a fuel with a lower heating value must be burned to meet the same heat demand. This affects fuel feeding, the combustion chamber, heat transfer surfaces and, at the design stage, boiler dimensions.

At ENORPA, we design the boiler around the selected fuel and target capacity. An existing boiler cannot deliver the same thermal output with every fuel. Achievable capacity is determined by assessing fuel properties, the burner or feeding system, and boiler design together.

Explore the heating values of different fuels
ENORPA 360° SUPPORT

From the first conversation throughout your equipment’s life.

We identify your needs together
and support you at every stage.

360°
ENORPA
SUPPORT SHIELD

Comprehensive support in four stages.
One engineering approach.

01 ANALYSIS & CONSULTANCY

The right decision
starts with an expert.

Speak directly with our specialist engineers and receive free advice. Let’s analyse your needs together and identify the right product and capacity for you.

02 CUSTOM MANUFACTURING & SUPPLY

Tailored to your needs.
Built for you.

Let’s turn your technical requirements into equipment made for you. We manufacture and supply your product and the necessary equipment to meet your specific needs.

03 INSTALLATION & COMMISSIONING

We install it. Get it running.
Prepare your team.

We install and commission the products you purchase from us, then train your personnel in their use and operation.

04 LIFETIME TECHNICAL SUPPORT

As your equipment keeps working,
our support continues.

When a fault occurs, we support you through our contracted local service providers or a technical team dispatched from our headquarters, depending on the nature of the issue. We provide technical support throughout the life of your equipment.

FREQUENTLY ASKED QUESTIONS

Before you
decide.

Can Obsidyen be manufactured for an intermediate capacity?

Within the series’ thermal output ranges of 750,000–5,000,000 kcal/h for solid fuel and 1,500–10,000 kW for liquid/gas fuel, a suitable capacity is engineered by assessing your requirements, fuel and operating conditions together.

Which feeding or combustion system is used?

Top-fed hydraulic ram feeding or burner. For solid fuel: a moving grate with water and air cooling, clinker crushing and ash discharge. Switching between fuels is possible; different fuels are not burned simultaneously.

Can different fuels be burned at the same time?

No. Switching between solid fuel and liquid/gas fuel is possible, but they are not burned simultaneously. Output ranges differ by fuel and are stated separately in the technical table.

Is a separate series required for hot water and high-temperature hot water?

A suitable configuration is considered within this series. Target water temperature, operating pressure and installation conditions are determined for each project; a single operating temperature must not be assumed for the entire series.

Which equipment is included in the delivery?

You can choose the boiler body alone, supply with auxiliary equipment, or a solution covering the boiler room. Whether the burner, feeding system, control panel, pumps, fans, flue and other equipment are included is specified individually in the technical proposal.

Are installation and personnel training provided?

Installation, electrical and automation connections, commissioning and operator training are planned according to the project’s service scope. The boundaries of the work are defined in the technical proposal and contract.

When does the warranty begin?

ENORPA-manufactured products carry a 24-month warranty against manufacturing defects. The warranty starts on the actual commissioning date accepted by ENORPA, but no later than two calendar months after delivery. Third-party equipment is subject to the relevant manufacturer’s warranty terms; ENORPA provides coordination.

How are documentation and conformity requirements determined?

The product’s operating conditions, configuration and project requirements form the basis of the assessment. The applicable documentation and scope of conformity are clarified in the order’s technical file.

How is technical support provided abroad?

Depending on the project and country conditions, local teams working under ENORPA supervision may be considered. A contracted local service provider or a technical team from Türkiye is assigned according to the nature of the fault. Service terms are defined in the contract.

Is an economizer included in the delivery?

An economizer is not assumed to be included as standard. Its suitability for the fuel and operating conditions is assessed, and any selected heat recovery equipment is listed separately in the technical proposal.

SAME PRODUCT FAMILY

Explore other water heating solutions.

FREE CONSULTATION

Let’s plan your Obsidyen project together.

Share your requirements with our engineers. Let’s clarify the fuel, capacity, site conditions and scope of supply together.

We can start with this information, if available

  • Heat demand for solid fuel · kcal/h
  • Heat demand for liquid/gas fuel · kW
  • Target supply and return temperatures · °C
  • Operating pressure · barG
  • Fuels to be used and any need to switch between them

If you do not know the exact values, we can clarify your requirements together.