Solid-Fuel Hot Water and High-Temperature Hot Water Boiler

Turkuaz.

Single-furnace construction tailored to your heating requirements.

Single-furnace construction with an air-cooled fixed grate. The same capacity range applies to manual-feed and stoker-fed versions.

Thermal output range200,000–1,750,000 kcal/h
Operating pressure1–16 barG
FuelSolid fuel
Manufacturing approachMade to order
DESIGN APPROACH

We design your boiler room as a complete system.

For Turkuaz, we assess your facility’s hot water or high-temperature hot water requirements, target supply and return temperatures, and operating pressure together. We plan the boiler with equipment that works as a coordinated system, from fuel feeding and water circulation to combustion air and the flue connection.

For the single-furnace construction, we select manual loading or an underfeed stoker to suit the fuel and operating arrangements. For stoker operation, we plan the boiler hopper, feed screw and combustion air together; for manual operation, we plan access for loading and ash removal. Additional equipment such as a ground-level hopper and conveyor is included in the feeding line only where specified in the project scope.

We engineer the water supply, return and expansion lines together with circulation, temperature control and pressure safety equipment. We determine hot water or high-temperature hot water operating conditions to suit the installation’s requirements, treating water quality, adequate circulation and maintenance access as part of the design.

The layout accounts for maintenance door opening, service clearances, ventilation and operator access to the controls. For solid-fuel operation, we also arrange fuel loading and ash removal areas for practical daily use. This allows us to plan the system as a whole, from installation through operation and maintenance. Final capacity, equipment selection and scope of supply are determined for each project and order.

Fully cylindricalScotch typeThree-passFire-tube
FUEL FEEDING & COMBUSTION

An operating arrangement
suited to your fuel.

  1. Transfer to the hopper: Fuel from the main coal pit is transferred to the hopper by a screw conveyor.
  2. Feeding the burn pot: Fuel in the hopper is fed from below into the burn pot by a feed screw driven by a geared motor.
  3. Air supply: The fresh air fan supplies air to the combustion zone through the outer air duct.
  4. Ignition: The operator ignites the fuel in the burn pot.
  5. Combustion with automatic feeding: Screw run and pause durations are set on the control panel; combustion is maintained by the fuel and air supply.
  6. Ash and clinker formation: As the fuel burns, ash and clinker accumulate around the burn pot.
  7. Cooling: After fuel feeding has stopped and combustion has ended, the system is allowed to cool.
  8. Ash and clinker removal: Once the system has cooled, the operator removes accumulated ash and clinker.

Small-capacity boilers do not have a screw conveyor transferring coal from the coal pit to the boiler hopper. This animation explains the general operating principle. Equipment may vary according to the order scope.

TECHNICAL SPECIFICATIONS

Capacity, pressure
and boiler construction.

Within its fully cylindrical shell, Turkuaz transfers heat from fuel combustion to water through a three-pass fire-tube arrangement. Operating conditions are engineered to meet the facility’s hot water or high-temperature hot water requirements. The sequence below describes the stoker-fed option; with manual feeding, the operator loads fuel onto the fixed grate.

Turkuaz technical specifications

Capacity and construction

Thermal output range200,000–1,750,000 kcal/h
Operating pressure1–16 barG
Operating water temperatureEngineered to suit hot water or high-temperature hot water requirements
ConstructionFully cylindrical · Scotch type · Three-pass · Fire-tube
FuelSolid fuel
Fuel feeding / combustionManual feeding or underfeed stoker
Solid-fuel lower heating value2,000–7,500 kcal/kg
Minimum fuel particle sizeGreater than 8 mm
Maximum fuel sizeUp to 500 mm with manual feeding; up to 35 mm with stoker feeding
ManufacturingEngineered to order
Product familyHot Water & High-Temperature Hot Water Boilers

Material standards

Boiler steels In high-pressure sections:EN 10028-2 grade P355GH, P295GH, P265GH and P235GH
Steel grades In non-pressurized or low-pressure sections:EN 10025-2 grade S355JR, S235JR
Fire and smoke tubesEN 10217-2 or EN 10216-2 grade P235GH

The series is engineered to order within a thermal output range of 200,000–1,750,000 kcal/h and an operating pressure range of 1–16 barG. These are the series limits of boilers that can be manufactured at different capacities; they do not represent the load adjustment range of a single boiler. Final capacity, operating temperature, pressure and equipment scope are determined for each project.

Fuel storage and transfer to the hopper

In a stoker-fed system, the fuel path starts at the boiler hopper. If the system also includes a ground-level hopper, the user loads fuel there; a transfer screw or conveyor moves it to the boiler hopper. If a level sensor is specified in the order, the transfer system starts automatically when the fuel level in the hopper falls.

The grid screen at the hopper inlet helps suitably sized fuel pass through. Sloping hopper walls help fuel flow towards the feeding point. Depending on the fuel type and flow properties, an agitator may be used in the ground-level or boiler hopper. Equipment such as the ground-level hopper, conveyor, sensor and agitator is determined by the order scope.

Screw underfeeding and combustion air

Fuel descending from the hopper into the screw channel is conveyed to the burn pot by the feed screw driven by the geared motor. Fuel rises through the pot to reach the combustion bed. Air from the fresh air fan travels through a separate air duct surrounding the screw tube and is distributed to the air openings in the pot. Heated along this path, the air meets the fuel in the combustion bed.

Combustion bed, ash and clinker formation

Initial ignition is performed by the operator; combustion is then maintained by fuel and air feeding. The extent and depth of the combustion bed are monitored during operation. An excessively thin bed may expose the feeding system to high temperatures.

Ash forms after combustion; depending on the fuel properties, some ash may fuse into clinker. Ash and clinker are removed after cooling on the cooling grate at the front. Inspection doors at the hopper-to-screw connection provide access to the fuel flow; maintenance doors around the fan and in front of the pot make it easier to inspect air passages and remove accumulated ash.

Three-pass gas path starting in the furnace

In the first pass, hot combustion gases travel along the furnace. They then reach the rear reversal chamber and are directed into the second-pass smoke tubes. The water-surrounded wet-back construction of this chamber contributes to the transfer of heat from the hot gases to the boiler water.

Gases from the second-pass tubes enter the front smoke box, change direction and pass into the third-pass tubes. At the end of the third pass, they reach the rear smoke box and then the flue connection duct. The water-surrounded surfaces of the front and rear smoke boxes contribute to heat transfer; refractory lining on the outward-opening maintenance doors limits heat loss through these surfaces.

Cyclone, flue gas fan and discharge

The route after the flue connection is arranged according to the boiler room design. Gases are directed either straight to the flue system or through a single cyclone or multicyclone where included. The cyclone separates some of the solid particles carried by the gas and collects them in a hopper.

The flue gas fan draws gases through the boiler and, where fitted, the cyclone, and sends them to the chimney. Dampers in the ducts allow flow adjustment, while cyclone doors provide access for cleaning and maintenance. The gases are finally discharged to the atmosphere through the chimney.

Heat transfer and hot water / high-temperature hot water circulation

Energy from hot gases in the furnace and smoke tubes is transferred to the boiler water surrounding these surfaces. Heated water is sent through the supply line to the installation to meet heating or process requirements. Operating temperature and pressure are determined together according to the hot water or high-temperature hot water requirement. In high-temperature hot water applications, system pressure is set so that water remains liquid at the target temperature.

After transferring its heat to the installation, water returns to the boiler through the return line, is reheated and re-enters circulation. Water guide channels inside the boiler limit direct impingement of cooler return water on the third-pass tubes and help direct it towards warmer areas. This arrangement is intended to reduce the risk of flue gas condensation on cold surfaces and the resulting corrosion.

Insulation and external cladding

The boiler shell is insulated with glass wool or stone wool according to the design conditions. Durable external cladding over the insulation is arranged to protect it from crushing and external influences. This limits heat released through the shell to the surroundings and helps retain the generated energy inside the boiler.

FUEL COMPATIBILITY

The right configuration
starts with your fuel.

Coal and lignite; wood, pellets and appropriately sized wood chips; olive pomace and agricultural biomass may be considered when the fuel conditions are met. Fuels containing plastic or unsuitable chemical additives are not accepted. A fuel name alone does not establish suitability; lower heating value, size, composition, moisture content and analysis requirements are assessed together.

Coal / LigniteWood / PelletsAgricultural biomass
Open the unit converter
SOLID FUELS · IEA · LOWER HEATING VALUE≈ 1,959–8,431 kcal/kg

Solid-fuel and feeding requirements

The product’s current range for project assessment is 2,000–7,500 kcal/kg; this is separate from the typical values in the IEA table. Fuel size must be greater than 8 mm. The maximum is 500 mm with manual feeding and 35 mm with stoker feeding.

When lower heating value changes, capacity may change too

All other conditions being equal, more of a fuel with a lower heating value must be burned to meet the same heat demand. Fuel moisture and ash content also affect combustion. The feeding system, combustion chamber, grate, heat transfer surfaces and boiler dimensions are therefore determined by the selected fuel.

At ENORPA, we design the boiler around the selected fuel and target capacity. A boiler cannot deliver the same thermal output with every solid fuel; achievable capacity is assessed together with the fuel analysis and feeding system.

Explore the heating values of different fuels
ENORPA 360° SUPPORT

From the first conversation throughout your equipment’s life.

We identify your needs together
and support you at every stage.

360°
ENORPA
SUPPORT SHIELD

Comprehensive support in four stages.
One engineering approach.

01 ANALYSIS & CONSULTANCY

The right decision
starts with an expert.

Speak directly with our specialist engineers and receive free advice. Let’s analyse your needs together and identify the right product and capacity for you.

02 CUSTOM MANUFACTURING & SUPPLY

Tailored to your needs.
Built for you.

Let’s turn your technical requirements into equipment made for you. We manufacture and supply your product and the necessary equipment to meet your specific needs.

03 INSTALLATION & COMMISSIONING

We install it. Get it running.
Prepare your team.

We install and commission the products you purchase from us, then train your personnel in their use and operation.

04 LIFETIME TECHNICAL SUPPORT

As your equipment keeps working,
our support continues.

When a fault occurs, we support you through our contracted local service providers or a technical team dispatched from our headquarters, depending on the nature of the issue. We provide technical support throughout the life of your equipment.

FREQUENTLY ASKED QUESTIONS

Before you
decide.

Can Turkuaz be manufactured for an intermediate capacity?

Within the series’ thermal output range of 200,000–1,750,000 kcal/h, a suitable capacity is engineered by assessing your requirements, fuel and operating conditions together.

Which feeding or combustion system is used?

Manual feeding or underfeed stoker. Single-furnace construction with an air-cooled fixed grate. The same capacity range applies to manual-feed and stoker-fed versions.

Do the manual-feed and stoker-fed versions have different capacities?

No. The thermal output range is 200,000–1,750,000 kcal/h for both feeding options. The choice depends on fuel size and operating arrangements.

Is a separate series required for hot water and high-temperature hot water?

A suitable configuration is considered within this series. Target water temperature, operating pressure and installation conditions are determined for each project; a single operating temperature must not be assumed for the entire series.

Which equipment is included in the delivery?

You can choose the boiler body alone, supply with auxiliary equipment, or a solution covering the boiler room. Whether the burner, feeding system, control panel, pumps, fans, flue and other equipment are included is specified individually in the technical proposal.

Are installation and personnel training provided?

Installation, electrical and automation connections, commissioning and operator training are planned according to the project’s service scope. The boundaries of the work are defined in the technical proposal and contract.

When does the warranty begin?

ENORPA-manufactured products carry a 24-month warranty against manufacturing defects. The warranty starts on the actual commissioning date accepted by ENORPA, but no later than two calendar months after delivery. Third-party equipment is subject to the relevant manufacturer’s warranty terms; ENORPA provides coordination.

How are documentation and conformity requirements determined?

The product’s operating conditions, configuration and project requirements form the basis of the assessment. The applicable documentation and scope of conformity are clarified in the order’s technical file.

How is technical support provided abroad?

Depending on the project and country conditions, local teams working under ENORPA supervision may be considered. A contracted local service provider or a technical team from Türkiye is assigned according to the nature of the fault. Service terms are defined in the contract.

Is an economizer included in the delivery?

An economizer is not assumed to be included as standard. Its suitability for the fuel and operating conditions is assessed, and any selected heat recovery equipment is listed separately in the technical proposal.

SAME PRODUCT FAMILY

Explore other water heating solutions.

FREE CONSULTATION

Let’s plan your Turkuaz project together.

Share your requirements with our engineers. Let’s clarify the fuel, capacity, site conditions and scope of supply together.

We can start with this information, if available

  • Heat demand · kcal/h
  • Target supply and return temperatures · °C
  • Operating pressure · barG
  • Solid-fuel type and properties

If you do not know the exact values, we can clarify your requirements together.