Solid-Fuel Steam Boiler

Kuvars Çift Külhanlı — Twin furnace.

Steam power for your process with a twin-furnace construction.

Twin-furnace construction with an air-cooled fixed grate. Manual and stoker-fed versions have the same capacity range.

Steam output range3,000–6,000 kg/h
Operating pressure1–16 barG
FuelSolid fuel
Manufacturing standardEN 12953
DESIGN APPROACH

We design your boiler room as a complete system.

For Kuvars Çift Külhanlı, we assess your process steam requirements, operating pressure and daily load variations together. We design the boiler as part of a coordinated boiler room, integrating fuel preparation, combustion air, feedwater, steam distribution and the flue system.

For the twin-furnace construction, we select manual loading or underfeed stoker feeding to suit the fuel and operating arrangements. For the stoker-fed version, we plan the boiler hopper, feed screw and combustion air together; for the manual version, we plan loading and ash removal access. Additional equipment such as a ground-level hopper and conveyor is included in the feeding line only when it forms part of the project scope.

We engineer feedwater treatment, pumping, steam discharge, condensate return and the necessary drain and blowdown lines together with the process installation. We ensure that water level and pressure control equipment is compatible with the boiler and feedwater system. Water quality, scale prevention and corrosion control form part of the operating plan.

The layout accounts for maintenance door opening, service clearances, ventilation and operator access to the controls. For solid-fuel operation, we also arrange fuel loading and ash removal areas to suit daily use. This allows us to plan the system as a whole, from installation through operation and maintenance. Final capacity, equipment selection and scope of supply are determined for each project and order.

Fully cylindricalScotch typeThree-passFire-tube
FUEL FEEDING & COMBUSTION

An operating arrangement
suited to your fuel.

  1. Transfer to the hopper: Fuel from the main coal pit is transferred to the hopper by a screw conveyor.
  2. Feeding the burn pot: Fuel in the hopper is delivered from below to the burn pot by a feed screw driven by a geared motor.
  3. Air supply: The fresh air fan supplies air to the combustion zone through the outer air duct.
  4. Ignition: The operator ignites the fuel in the burn pot.
  5. Combustion with automatic feeding: Screw operating and stop times are set on the control panel; fuel and air supply maintain combustion.
  6. Ash and clinker formation: Ash and clinker accumulate around the burn pot as fuel burns.
  7. Cooling: After fuel feeding stops and combustion ends, the system is allowed to cool.
  8. Ash and clinker removal: Once the system has cooled, the operator removes the accumulated ash and clinker.

Small-capacity boilers do not have a screw conveyor transferring coal from the coal pit to the boiler hopper. This animation explains the system’s general operating principle. Equipment may vary according to the order scope.

TECHNICAL SPECIFICATIONS

Capacity, pressure
and boiler construction.

Kuvars Çift Külhanlı is designed for steam generation with a fully cylindrical, Scotch-type, three-pass, fire-tube construction. Fuel preparation, combustion and heat transfer are engineered together around the selected capacity and the facility’s operating conditions.

Kuvars Çift Külhanlı technical specifications

Capacity and construction

Steam output range3,000–6,000 kg/h
Operating pressure1–16 barG
ConstructionFully cylindrical · Scotch type · Three-pass · Fire-tube
FuelSolid fuel
Fuel feeding / combustionManual feeding or underfeed stoker
Solid-fuel lower heating value2,000–7,500 kcal/kg
Minimum fuel particle sizeAbove 8 mm
Maximum fuel sizeUp to 500 mm with manual feeding, up to 35 mm with stoker feeding
ManufacturingEngineered to order
Product familySteam Boilers & Generators

Material standards

Boiler steels In high-pressure sections:EN 10028-2 grade P355GH, P295GH, P265GH and P235GH
Steel grades In non-pressurized or low-pressure sections:EN 10025-2 grade S355JR, S235JR
Fire and smoke tubesEN 10217-2 or EN 10216-2 grade P235GH

The series is engineered to order within a steam output range of 3,000–6,000 kg/h and an operating pressure range of 1–16 barG. These are the series limits for units manufactured at different capacities, not the load adjustment range of a single unit. Final capacity, operating conditions and equipment scope are determined for each project.

Fuel storage and transfer to the hopper

In the stoker-fed arrangement, fuel is stored in the boiler hopper. At facilities with an additional ground-level hopper and transfer system, fuel is carried to the boiler hopper by a screw or conveyor. Sloping surfaces help fuel flow towards the feeding point.

Fuel size and flow properties must be compatible with the feeding system. Auxiliary equipment such as conveyors, agitators and level sensors is not assumed to be standard in every delivery; its scope is determined for each order.

Twin furnaces and feeding options

Kuvars Çift Külhanlı operates with two furnaces in the same boiler body. In the stoker-fed version, fuel is taken from the hopper outlet and fed from below into the burn pots by screws; air supplied by the fan is distributed to the combustion bed.

In the manual version, the operator loads fuel onto the air-cooled fixed grate. Manual and stoker-fed versions have the same series output range; fuel size and loading arrangements depend on the selected feeding system.

Combustion bed and ash and clinker removal

In the stoker-fed arrangement, the operator performs initial ignition; fuel and air supply then maintain combustion. Fuel bed distribution and combustion conditions are monitored during operation. Feeding is adjusted to the properties of the fuel used.

Combustion produces ash; depending on fuel properties, some of it may form clinker. Removing deposits and keeping air passages clear are part of regular maintenance. Ash and clinker are removed after the system has cooled, in accordance with the operating instructions.

Three-pass fire and flue gas path

Hot gases from the combustion chamber travel through the three-pass fire-tube construction. Reversal sections direct the gases into the next pass, allowing them to contact the heat transfer surfaces before reaching the outlet.

Energy from the hot gases is transferred to the boiler water surrounding the fire and smoke tubes and combustion surfaces. Cleaning the flue gas passages, checking deposits on heat transfer surfaces and providing maintenance access form part of the operating plan.

Flue gas discharge and auxiliary equipment

For solid-fuel operation, the flue gas line may include a single cyclone or multicyclone, depending on the project scope. This equipment separates some of the solid particles carried by the gas and collects them in a hopper. Flue and duct dimensions, gas flow rate and system pressure losses are assessed together.

Where a flue gas fan is required, it is selected for the combined resistance of the boiler and auxiliary equipment. Fan, damper and cleaning access arrangements are determined for each project; auxiliary equipment must not automatically be assumed to be included in standard delivery.

Feedwater and steam generation

Water surrounding the heat transfer surfaces turns into steam when it reaches the boiling temperature corresponding to the operating pressure. The steam is supplied to the process line, and the feedwater system replenishes the water used. Pressure and feedwater control and safety equipment are arranged according to the selected design.

Feedwater quality is important for controlling scale formation and corrosion on heat transfer surfaces. Water treatment, condensate return and the necessary drain and blowdown arrangements are engineered around site conditions. Operation and maintenance must follow the product’s instructions.

Insulation, external cladding and maintenance access

To limit heat loss, hot surfaces are protected with insulation and external cladding suited to the design conditions. Insulation material, thickness and cladding details are determined by operating temperature and order scope.

Maintenance access must be provided to the combustion system, heat transfer surfaces and flue connections. Service clearances around equipment, door opening directions and cleaning areas are considered when preparing the facility layout.

FUEL COMPATIBILITY

The right configuration
starts with your fuel.

Coal and lignite; wood, pellets and suitably sized wood chips; olive pomace and agricultural biomass may be considered when fuel requirements are met. Fuels containing plastic or unsuitable chemical additives are not accepted. A fuel’s name alone does not establish suitability; lower heating value, size, composition, moisture content and analysis requirements are assessed together.

Coal / LigniteWood / PelletsAgricultural biomass
Open the unit converter
SOLID FUELS · IEA · LOWER HEATING VALUE≈ 1,959–8,431 kcal/kg

Solid-fuel and feeding requirements

The product’s current project assessment range is 2,000–7,500 kcal/kg; this is separate from the typical values in the IEA table. Fuel size must be above 8 mm. The maximum is 500 mm for manual feeding and 35 mm for stoker feeding.

When lower heating value changes, capacity may change too

All other conditions being equal, more of a fuel with a lower heating value must be burned to meet the same heat demand. Fuel moisture and ash content also affect combustion. The feeding system, combustion chamber, grate, heat transfer surfaces and boiler dimensions are therefore determined for the selected fuel.

At ENORPA, we design the boiler around the selected fuel and target capacity. A boiler cannot deliver the same thermal output with every solid fuel; achievable capacity is assessed together with the fuel analysis and feeding system.

Explore the heating values of different fuels
ENORPA 360° SUPPORT

From the first conversation throughout your equipment’s life.

We identify your needs together
and support you at every stage.

360°
ENORPA
SUPPORT SHIELD

Comprehensive support in four stages.
One engineering approach.

01 ANALYSIS & CONSULTANCY

The right decision
starts with an expert.

Speak directly with our specialist engineers and receive free advice. Let’s analyse your needs together and identify the right product and capacity for you.

02 CUSTOM MANUFACTURING & SUPPLY

Tailored to your needs.
Built for you.

Let’s turn your technical requirements into equipment made for you. We manufacture and supply your product and the necessary equipment to meet your specific needs.

03 INSTALLATION & COMMISSIONING

We install it. Get it running.
Prepare your team.

We install and commission the products you purchase from us, then train your personnel in their use and operation.

04 LIFETIME TECHNICAL SUPPORT

As your equipment keeps working,
our support continues.

When a fault occurs, we support you through our contracted local service providers or a technical team dispatched from our headquarters, depending on the nature of the issue. We provide technical support throughout the life of your equipment.

FREQUENTLY ASKED QUESTIONS

Before you
decide.

Can Kuvars Çift Külhanlı be manufactured for an intermediate capacity?

Within the series’ steam output range of 3,000–6,000 kg/h, a suitable capacity is engineered by assessing your requirements, fuel and operating conditions together.

Which feeding or combustion system is used?

Manual feeding or underfeed stoker. Twin-furnace construction with an air-cooled fixed grate. Manual and stoker-fed versions have the same capacity range.

Do manual and stoker-fed versions have different capacities?

No. The 3,000–6,000 kg/h output range applies to both feeding options. Selection depends on fuel size and operating arrangements.

Which equipment is included in the delivery?

You can choose the boiler body alone, supply with auxiliary equipment, or a solution covering the boiler room. Whether the burner, feeding system, control panel, pumps, fans, flue and other equipment are included is specified individually in the technical proposal.

Are installation and personnel training provided?

Installation, electrical and automation connections, commissioning and operator training are planned according to the project’s service scope. The boundaries of the work are defined in the technical proposal and contract.

When does the warranty begin?

ENORPA-manufactured products carry a 24-month warranty against manufacturing defects. The warranty starts on the actual commissioning date accepted by ENORPA, but no later than two calendar months after delivery. Third-party equipment is subject to the relevant manufacturer’s warranty terms; ENORPA provides coordination.

How are documentation and conformity requirements determined?

The product’s operating conditions, configuration and project requirements form the basis of the assessment. The applicable documentation and scope of conformity are clarified in the order’s technical file.

How is technical support provided abroad?

Depending on the project and country conditions, local teams working under ENORPA supervision may be considered. A contracted local service provider or a technical team from Türkiye is assigned according to the nature of the fault. Service terms are defined in the contract.

Is an economizer included in the delivery?

An economizer is not assumed to be included as standard. Its suitability for the fuel and operating conditions is assessed, and any selected heat recovery equipment is listed separately in the technical proposal.

SAME PRODUCT FAMILY

Explore other steam solutions.

FREE CONSULTATION

Let’s plan your Kuvars Çift Külhanlı project together.

Share your requirements with our engineers. Let’s clarify the fuel, capacity, site conditions and scope of supply together.

We can start with this information, if available

  • Steam requirement · kg/h
  • Operating pressure · barG
  • Solid-fuel type and properties

If you do not know the exact values, we can clarify your requirements together.